Neurotoxicity Of Synthetic Cannabinoids JWH-081 And JWH-210

Aus Erkenfara
Version vom 23. Mai 2026, 05:29 Uhr von CindaBeor09 (Diskussion | Beiträge) (Die Seite wurde neu angelegt: „A 30-min period, beginning when maximal depression of locomotor activity first appeared as a function of dose, was used for analysis of dose-response data and…“)
(Unterschied) ← Nächstältere Version | Aktuelle Version (Unterschied) | Nächstjüngere Version → (Unterschied)
Zur Navigation springen Zur Suche springen

A 30-min period, beginning when maximal depression of locomotor activity first appeared as a function of dose, was used for analysis of dose-response data and calculation of ED50 values. During test sessions, both levers were active, such that ten consecutive responses on either lever led to 4F ADB reinforcement. The substitution tests occurred only if the rats had achieved 85% injection-appropriate responding on the two prior training sessions.
The locomotor activity assay was used to identify approximate time courses and dose ranges of psychoactive effects, which is useful for identifying parameters for drug discrimination experiments and are also predictive of the time course of the psychoactive effects in human users. The purpose of the present study was to assess the abuse liability of 5F-MDMB-PINACA, MDMB-CHIMICA, MDMB-FUBINACA, ADB-FUBINACA, and AMB-FUBINACA. Since there is currently no robust measure of the reinforcing/rewarding effects of cannabinoids, drug discrimination is currently the best model for assessing abuse liability of cannabinoids. The findings produce an apparent paradox, since CPP and self-administration predict with high reliability the likelihood that a compound will be abused by humans, and cannabinoids are well-known to produce active drug-seeking in human


Test 2 was performed everyday for 5 days after consecutive administration of the substances, including negative (vehicle) and positive (methamphetamine) controls. After the last administration, the first trial was performed. Morris water maze test was performed to evaluate the changes of learning and memory function through administration of the test substances. Generally, neurotoxicity of a substance is evaluated by animal behavioral aspects, i.e. functional observation battery (FOB) tests (O’Callaghan et al., 2014). Our results suggest that JWH-081 and JWH-210 may 4F ADB be neurotoxic substances through changing neuronal cell damages, especially in the core shell part of nucleus accumbens.
About Powder JWH-2


In the present study, we performed various methods based on animal behavioral testing including FOB test for general behavioral observation, rotarod test, locomotor activity test for motor function evaluation, and water-maze test for learning/memory evaluation. Known for its stability and consistent composition, this compound is frequently utilized by professionals seeking reliable materials for laboratory-based analytical studies. In this study, histopathological evaluation was performed to confirm the possibility of neurotoxicity of the tested substances by hematoxylin and eosin staining method from collected brain samples. In the present study, we evaluated the neurotoxicity of two synthetic cannabinoids (JWH-081 and JWH-210) through observation of various behavioral changes and analysis of histopathological changes using experimental mice with various doses (0.1, 1, 5 mg/kg). Selecting powder JWH-210 demands careful evaluation of purity, legality, and supplier credibility. Prices for research-grade JWH-210 vary significantly based on quantity, purity, and vendor complianc


Inclusion in an NLM database does not imply endorsement of, or agreement with, the contents by NLM or the National Institutes of Health. It is illegal to sell, distribute, supply, transport or trade the pharmaceutical drug under the Psychoactive Substances Act 2016. The corresponding indole core analogue, 4F-MDMB-BICA (4F-MDMB-BUTICA), has also been widely sold as a designer drug by chemical providers on the internet, first being identified in May 2020. It has been used as an active ingredient in synthetic cannabis products and sold as a designer drug since late 2018. 4F-MDMB-BINACA (also known as MDMB-4F-BINACA using systematic EMCDDA nomenclature or 4F-MDMB-BUTINACA) is an indazole-based synthetic cannabinoid from the indazole-3-carboxamide family.
Fig.


Product ions detected at m/z 302, 217, and 145 (B2) confirmed that tert-leucine and indazole moieties remained unchanged, leading to the structure elucidation of a hydroxy-functional group at the 4-position of the butyl side chain by oxidative defluorination. The product ion m/z 336 (loss of methyl ester moiety) further confirmed the presence of dihydroxylated metabolites. The precursor ion, m/z 364 (B14, B5/B6) had a loss of 2 Da from m/z 366 indicated further dehydrogenation of the ester hydrolysis plus monohydroxylated metabolites. The presence of the product ion m/z 320, likely formed from a loss of carbon dioxide, indicated monohydroxylation at the tert-leucine in B8 (m/z 219), butyl side chain in B9 (m/z 145) and indazole moiety in B13 (m/z 161). The precursor ion, m/z 350 showed a loss of 14 Da explaining the hydrolysis of methyl ester from 4F-MDMB-BINACA.
Fig. 2.
4F-MDMB-BINACA was hydrolysed via ester hydrolysis forming the 4F-MDMB-BINACA ester hydrolysis metabolite (B22). Data obtained from the twenty urine samples were retrospectively analysed and processed using TraceFinder software based on the identification criteria of mass errors less than ± 5 ppm for full MS peaks and MS/MS peaks from the theoretical mass and matching of MS/MS spectra. The mixture was vortex-mixed and 500 µL of this mixture and 500 µL of methanol were loaded onto the Clean Screen FASt® tube. After incubation, the mixture was cooled at room temperature, and 150 µL of purified water was added. High-resolution QTOF-MS data were acquired on an Agilent 6510 Accurate Mass QTOF mass spectrometer (Agilent Technologies) equipped with dual electrospray ionization (ESI) source operated in both positive and negative ion modes, to determine accurate masses of the metabolites. Chromatographic separation was performed on an Agilent 1290 LC system with a Poroshell 120 EC-C18 analytical column (2.7 μm, 75 × 2.1 mm; Agilent Technologies, Santa Clara, CA, USA).
Fig. 1.
This outcome was anticipated since CES-mediated hydrolysis is commonly 4F ADB reported as the major metabolic pathway among the SCBs impacting the terminal ester group . Glucosides and sulfate metabolites have been reported with other SCBs where C. From these three samples, sample 2 contained only an ester hydrolysis metabolite (m/z 350). Both ester hydrolysis followed by oxidative defluorination to butanoic acid (B4, m/z 362) and monohydroxylation at tert-leucine moiety (B8, m/z 366) metabolites were found in 16/20 urine samples (Table 2). A In-vitro metabolites observed in common among respective seven most abundant metabolites in b C. The product ion detected at m/z 235, indicating loss of sulfate, confirmed the identity of the sulfation metabolite.
Fungus C. elegans
Methyl (2S)-2-([1-(4-fluorobutyl)-1H-indazole-3-carbonyl]amino)-3,3-dimethylbutanoate (4F-MDMB-BINACA, 4F-MDMB-BUTINACA or 4F-ADB), found in numerous SCB product seizures, has been reported by various law enforcement since 2018 . However, most of the SCBs are full agonists at CB1 and CB2 receptors, having a higher risk of undesirable side effects when compared to THC which is a partial agonist . Synthetic cannabinoids (SCBs) are agonists at cannabinoid receptor type 1 (CB1) and type 2 (CB2), where they elicit their main effect